Differential Polarization Laser Scanning Microscopy
Bioimaging (Talk | contribs) m |
Bioimaging (Talk | contribs) m |
||
(3 intermediate revisions by one user not shown) | |||
Line 4: | Line 4: | ||
|Facility_desc=DP-LSM | |Facility_desc=DP-LSM | ||
|Organization=Biological Research Centre of HAS | |Organization=Biological Research Centre of HAS | ||
− | |Website=http://www.dplsm. | + | |Website=http://www.dplsm.eu/ |
|Street=Temesvári krt. 62. | |Street=Temesvári krt. 62. | ||
|ZIP=H-6726 | |ZIP=H-6726 | ||
|City=Szeged | |City=Szeged | ||
− | |Facility_Head= | + | |Facility_Head=GARAB,_Győző_Prof._Dr. |
|Pricelist=DP-LSM Pricelist | |Pricelist=DP-LSM Pricelist | ||
}} | }} | ||
The DP-LSM is a ’conventional’ laser scanning confocal microscope '''(LSM)''' equipped with laboratory-built high-frequency differential-polarization '''(DP)''' attachments. This set-up allows the rapid and precise pixel-by-pixel determination of physical parameters which are characteristic of the anisotropic molecular architecture of different samples, i.e. parameters derived from DP measurements and from the interaction of the sample with polarized light in general. With the aid of DP-LSM, in addition to the conventional LSM imagings, 2D or 3D maps can be obtained on the birefringence (LB), linear and circular dichroism (LD&CD) of the sample, also, confocally, on fluorescence-detected dichroisms (FDLD&FDCD), as well as the linear and circular polarization contents of the emission (r&CPL), as well as on the degree of polarization of fluorescence emission. | The DP-LSM is a ’conventional’ laser scanning confocal microscope '''(LSM)''' equipped with laboratory-built high-frequency differential-polarization '''(DP)''' attachments. This set-up allows the rapid and precise pixel-by-pixel determination of physical parameters which are characteristic of the anisotropic molecular architecture of different samples, i.e. parameters derived from DP measurements and from the interaction of the sample with polarized light in general. With the aid of DP-LSM, in addition to the conventional LSM imagings, 2D or 3D maps can be obtained on the birefringence (LB), linear and circular dichroism (LD&CD) of the sample, also, confocally, on fluorescence-detected dichroisms (FDLD&FDCD), as well as the linear and circular polarization contents of the emission (r&CPL), as well as on the degree of polarization of fluorescence emission. | ||
+ | |||
+ | ''Main services:'' access to the instrument(s)<br /> measurements <br /> consultation <br />training programs Measurements on the Differential Polarization Laser Scanning Microscope (DP-LSM)<br /> Polarization spectroscopic measurements and assistance in sample preparation and characterization | ||
'''Area of science:'''<br /> | '''Area of science:'''<br /> |
Latest revision as of 11:09, 27 March 2014
Location Details |
---|
Fatal error: Parameter coordinates must be one or more valid locations. |
Contents |
[edit] DP-LSM
[website::http://www.dplsm.eu/]
[edit] Address
Differential Polarization Laser Scanning Microscopy
Biological Research Centre of HAS
Temesvári krt. 62.
H-6726
Szeged
GARAB,_Győző_Prof._Dr.
[edit] Head of Group
Prof. Győző Garab
Position: Head of Facility
Gyozo@brc.hu
Office: +36-62-433131 (direct), +36-62-599600 (operator), +36-30-2077787 (mobile)
[edit] Equipment
Count | Description | |
---|---|---|
DP-LSM | 1 | Laser Scanning Microscope |
JASCO 815 spectropolarimeter | 1 | Spectropolarimeter |
Shimadzu UV-VIS 3000 | 1 | Spectrometer |
Spectrometer | 1 | Spectrometer |
Spectropolarimeter | 1 | Dichrograph |
[edit] Group Members
GARAB, Győző Prof. Dr. | Gyozo@brc.hu | +36-62-433131 (direct), +36-62-599600 (operator), +36-30-2077787 (mobile) |
[edit] Details
[edit] Price List
[edit] About the facility
The DP-LSM is a ’conventional’ laser scanning confocal microscope (LSM) equipped with laboratory-built high-frequency differential-polarization (DP) attachments. This set-up allows the rapid and precise pixel-by-pixel determination of physical parameters which are characteristic of the anisotropic molecular architecture of different samples, i.e. parameters derived from DP measurements and from the interaction of the sample with polarized light in general. With the aid of DP-LSM, in addition to the conventional LSM imagings, 2D or 3D maps can be obtained on the birefringence (LB), linear and circular dichroism (LD&CD) of the sample, also, confocally, on fluorescence-detected dichroisms (FDLD&FDCD), as well as the linear and circular polarization contents of the emission (r&CPL), as well as on the degree of polarization of fluorescence emission.
Main services: access to the instrument(s)
measurements
consultation
training programs Measurements on the Differential Polarization Laser Scanning Microscope (DP-LSM)
Polarization spectroscopic measurements and assistance in sample preparation and characterization
Area of science:
Engineering sciences : Materials science and technology
Chemical sciences : Other chemical sciences
Experimental medicine : Medical biology, Medical microbiology
Biotechnology : Environmental biotechnology, Animal biotechnology, Plant biotechnology, Medical biotechnology, Agricultural biotechnology
Biology : Microbiology, Evolutionary biology, Molecular biology, Structural biology,
Other life sciences: Cell biology