MicroCT at the Semmelweis University
Bioimaging (Talk | contribs) m |
Bioimaging (Talk | contribs) m |
||
Line 10: | Line 10: | ||
|Facility_Head=DOBÓ NAGY, Csaba Dr. | |Facility_Head=DOBÓ NAGY, Csaba Dr. | ||
}} | }} | ||
− | MicroCT provides high resolution 3D image data of samples without destruction. | + | The MicroCT provides high resolution 3D image data of samples without destruction. Its typical applications include: hard tissues, pills, minerals, microfossils, ICs and ex vivo soft tissues filled with contrast media. Its parameters are: X-ray source - 20-100 kV; microfocus - <5 micrometer; X-ray detector -12 bits and there is an 1.3 Mpixel cooled CCD optically coupled to the scintillator. Its maximum sample size is 68 mm length, 37 mm diameter and the smallest voxel size depends on the diameter of the sample (between 2-30 micrometer). It utilises a Feldkamp reconstruction algorithm. |
<br /> | <br /> | ||
Revision as of 10:06, 31 March 2014
Location Details |
---|
Loading map...
|
Contents |
SE micro-CT
[website::http://www.microct.hu/]
Address
MicroCT at the Semmelweis University
Semmelweis University
Szentkirályi utca 47.
H-1088
Budapest
DOBÓ NAGY, Csaba Dr.
Head of Group
Dr. Dobó Nagy Csaba
Position: Head of Facility
Dobo-nagy.csaba@dent.semmelweis-univ.hu
Office: +36 70 3158784
Equipment
Count | Description | |
---|---|---|
Cone-beam CT | 1 | CT |
Micro CT | 1 | CT |
Scanning electron microscope | 1 | Electron microscope |
Group Members
DOBÓ NAGY, Csaba Dr. | Dobo-nagy.csaba@dent.semmelweis-univ.hu | +36 70 3158784 |
Details
Price List
About the facility
The MicroCT provides high resolution 3D image data of samples without destruction. Its typical applications include: hard tissues, pills, minerals, microfossils, ICs and ex vivo soft tissues filled with contrast media. Its parameters are: X-ray source - 20-100 kV; microfocus - <5 micrometer; X-ray detector -12 bits and there is an 1.3 Mpixel cooled CCD optically coupled to the scintillator. Its maximum sample size is 68 mm length, 37 mm diameter and the smallest voxel size depends on the diameter of the sample (between 2-30 micrometer). It utilises a Feldkamp reconstruction algorithm.
Area of science:
Engineering sciences : Materials science and technology
Earth sciences : Geochemistry, mineralogy and petrology
Biology : Anatomy and antropology, Physiology
Experimental medicine : Other experimental medicine, Medical biology
Clinical medicine : Ondotology, Operative medicine
Agronomics : Cultivation sciences, Veterinary sciences